Section 6 Interface to Application

60

6.6.4

Circuit Seized Indication

This primitive is used by ISUP to indicate that the circuit has been seized for

an incoming call (but no address information has yet been received) and a
continuity test call has been received (refer to

Section

6.8.4:

Continuity

Testing on page 95

).

Message type

SZE (Circuit seized)

Mandatory parameters

• Nature of connection indicators

Optional parameters

None

6.6.5

Collection Charging Indication

This primitive is used ISUP after alerting to convey the number of charging

units.

Message type

MPM (Collection Charging Message)

Mandatory parameters

• Number of metering pulses
• Message number

Optional parameters

None

6.6.6 Confusion

Indication

This primitive is issued by ISUP on receipt of a Confusion message from the

network.

Message type

CFN (Confusion Message)

Mandatory parameters

None

Optional parameters

• Cause Indicators