Figure 1, Notation used for parameter specifications – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 85

Advertising
background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

85

Value

Length

Parameter Name

Hex

Dec

Definition/Reference

Min

Max

Notes

User service information
prime

0x30

48

Q.763 Section 3.58

2

11

1

User-to-user indicators

0x2a

42

Q.763 Section 3.53

1

1

-

User-to-user information

0x20

32

Q.763 Section 3.61

1

129

1

User teleservice
information

0x34

52

Q.763 Section 3.59

2

3

1

Notes

• The ISUP module transports this parameter transparently without

verifying its format.

• The length of this parameter depends on the length of a point code.
• This parameter is generated within the ISUP module and is not passed

across the user interface.

• This parameter may be repeated. Refer to Appendix E for further

information.

• The minimum length of this parameter may differ depending on the ISUP

variant used:

Minimum Parameter Length

Parameter Name

ITU

ANSI

Called party number

2

1

Originating line information

-

1

Signalilng point code

2

3

Figure 1.

Notation used for Parameter Specifications

The notation used for the parameter specifications is shown below:

MSB

7 6 5 4 3 2

LSB

Parameter name and value

Parameter length (in octets)

1

First octet of parameter

2

:

n

Final octet of parameter