H3C Technologies H3C S3100 Series Switches User Manual
Page 794

1-8
Operation
Command
Description
Log host
direction
info-center timestamp loghost
date
Set the time stamp
format in the output
direction of the
information center to
date
Non log host
direction
info-center timestamp { log | trap
| debugging } date
Required
Use either command
Set to display the UTC time zone in the
output information of the information
center
info-center timestamp utc
Required
By default, no UTC time
zone is displayed in the
output information
Setting to Output System Information to the Console
Setting to output system information to the console
Table 1-7 Set to output system information to the console
Operation
Command
Description
Enter system view
system-view
—
Enable the information center
info-center enable
Optional
Enabled by default.
Enable system information
output to the console
info-center console channel
{ channel-number | channel-name }
Optional
By default, the switch uses information
channel 0 to output
log/debugging/trap information to the
console.
Configure the output rules of
system information
info-center source { modu-name |
default } channel
{ channel-number | channel-name }
[ { log | trap | debug } { level
severity | state state } ]*
Optional
Refer to
for the default
output rules of system information.
Set the format of time stamp in
the output information
info-center timestamp { log | trap
| debugging } { boot | date |
none }
Optional
By default, the time stamp format of
the log and trap output information is
date, and that of the debugging output
information is boot.
To view the debugging information of some modules on the switch, you need to set the type of the
output information to debug when configuring the system information output rules, and use the