HEIDENHAIN TNC 335 Technical Manual User Manual
Page 153

4-56
TNC 360
3 Servo Positioning of the NC Axes
8/95
MP1810
Kv factor for operation with lag
Input range 0.1 to 10 [1/min]
MP1810.0
k
v
factor X axis
MP1810.1
k
v
factor Y axis
MP1810.2
k
v
factor Z axis
MP1810.3
k
v
factor 4th axis
MP1010
Rapid traverse
Input range 80 to 300 000 [mm/min]
MP1010.0
Rapid traverse X axis
MP1010.1
Rapid traverse Y axis
MP1010.2
Rapid traverse Z axis
MP1010.3
Rapid traverse 4th axis
MP1050
Analog voltage for rapid traverse
Input range 4.5 to 9 [V]
MP1050.0
Analog voltage X axis
MP1050.1
Analog voltage Y axis
MP1050.2
Analog voltage Z axis
MP1050.3
Analog voltage 4th axis
MP1020
Manual feed
Input range 80 to 300 000 [mm/min]
MP1020.0
Manual feed X axis
MP1020.1
Manual feed Y axis
MP1020.2
Manual feed Z axis
MP1020.3
Manual feed 4th axis
Address
Function
D596
Rapid traverse from PLC
Servo accuracy:
The internal servo accuracy of the control is always 1 µm. The control has, however, a display step
of 5 µm or 1 µm, selectable by machine parameter MP7290. The rounding up or down is only in the
display (see section "Display and operation").
Normally a servo accuracy of 1 µm is sufficient, i.e. the control must be able to generate at least one
voltage step per 1 µm positional deviation.