4-56

TNC 360

3 Servo Positioning of the NC Axes

8/95

MP1810

Kv factor for operation with lag
Input range 0.1 to 10 [1/min]

MP1810.0

k

v

factor X axis

MP1810.1

k

v

factor Y axis

MP1810.2

k

v

factor Z axis

MP1810.3

k

v

factor 4th axis

MP1010

Rapid traverse
Input range 80 to 300 000 [mm/min]

MP1010.0

Rapid traverse X axis

MP1010.1

Rapid traverse Y axis

MP1010.2

Rapid traverse Z axis

MP1010.3

Rapid traverse 4th axis

MP1050

Analog voltage for rapid traverse
Input range 4.5 to 9 [V]

MP1050.0

Analog voltage X axis

MP1050.1

Analog voltage Y axis

MP1050.2

Analog voltage Z axis

MP1050.3

Analog voltage 4th axis

MP1020

Manual feed
Input range 80 to 300 000 [mm/min]

MP1020.0

Manual feed X axis

MP1020.1

Manual feed Y axis

MP1020.2

Manual feed Z axis

MP1020.3

Manual feed 4th axis

Address

Function

D596

Rapid traverse from PLC

Servo accuracy:
The internal servo accuracy of the control is always 1 µm. The control has, however, a display step
of 5 µm or 1 µm, selectable by machine parameter MP7290. The rounding up or down is only in the
display (see section "Display and operation").

Normally a servo accuracy of 1 µm is sufficient, i.e. the control must be able to generate at least one
voltage step per 1 µm positional deviation.