Machine control panel, 2 machine control panel – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 246

8/95
TNC 360
8 Key Simulation
4-149
8.2 Machine control panel
A manufacturer's specific machine control panel can be connected to the HEIDENHAIN contouring
controls. See Chapter "Mounting and electrical installation".
24 PLC inputs (I 128 to I 151) and 8 PLC outputs (O 0 to O 7) are available on the female connector
X27 for the evaluation of the keys on the machine control panel. The evaluation of the signals from
the machine control panel must be performed in the PLC program. The appropriate markers will be
set thereby. For safety reasons a complement marker must be reset when some functions are
activated. This is especially so for keys with several contacts. If the complement marker is not
properly set or reset, the flashing error message "Error in PLC program" will appear. The displayed
code identifies the marker where the error has occurred.
An axis direction key which has been operated can be stored by marker M2450 (Complement
marker M2466) . This means that the axis will be traversed until NC STOP occurs. This memory
function must be activated by machine parameter MP7680 Bit 0.
MP7680 - Memory function for axis-direction keys, memory function for
Input: 0 or 1
+ 0 = Not stored
+ 1 = Stored
Marker
Function
Error
message
Set
Reset
M2448
NC start (edge evaluation)
1A
PLC
PLC
M2464
Complement NC start
M2449
Rapid traverse
1B
M2465
Complement – rapid traverse
M2488
NC stop (“0” signifies stop)
–
M2450
Memory function for axis-direction keys
1C
M2466
Complement – memory function for axis-
direction keys
M2451
Feed release for all axes
1D
M2467
Complement – feed release
M2456
Manual traverse X+
1I
M2472
Complement - manual traverse X+
M2457
Manual traverse X-
1J
M2473
Complement - manual traverse X-
M2458
Manual traverse Y+
1K
M2474
Complement - manual traverse Y+
M2459
Manual traverse Y-
1L
M2475
Complement - manual traverse Y-