HEIDENHAIN TNC 335 Technical Manual User Manual

Page 338

Advertising
background image


8/95

TNC 360

16 Commissioning and Start-up Procedure

4-241

Connect storage oscilloscope to tachometer

of servo-amplifier of X axis.

Enter following program in

"PROGRAMMING AND EDITING"

operating mode:

LBL 1
X 100

1)

R0 F MAX

X 0 R0 F MAX
CALL LBL 1 REP 100/100

Press machine START button in the

"PROGRAM RUN/FULL SEQUENCE"

operating mode.

Machine runs.

MP1520: Increase entry value until the position is clearly traversed when
approaching. The overshoot can also be observed in the actual value display.

MP1520: Reduce the entry value until the position is no longer traversed.

U [V]

t [ms]

Check axes Y, Z and IV and correct MP1530, if necessary.

t [ms]

Tacho voltage U [V]

1)

Program the traverse paths for the axis concerned as large as possible.