D-83292

31-o

SERVICE MANUAL TNC

Issue:

01.09.1995

Page 100

Loosen/remove the fixing screws

Loosen fixing screws

Remove
knurled screw

E

knurled screw

Loosen

fixing screws

Lift out the PLC and graphics board.
Insert the new board.

Mounting the PLC and Graphics Board

The PLC and graphics board is mounted in the reverse order that is was dismounted,

a) Insert and secure the CLP board.

Engage the connectors.

Observe that no connectors are switched!

Close the logic unit and close the lock.

Switch on the main switch.
Offset adjustment with code number (see section 16.5).

Exchange is now finished.

NOTE:
Send and store the boards only in the

original packaging that protects them from acquiring

static charge. Never use conventional plastics to wrap the boards in.