Has responded, Ceeded (determined in mp, Operation with servo lag – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 147
Advertising
Operation with Servo Lag
Function
MP
A
B
C
D E
F
Input
AE-6
No.
Bit
Entry Value
Position monitoring during
operation with servo lag
cancellable (POSITIONING ERROR)
X
Y
Z
IV
V
1710
1710.0
1710.1
1710.2
1710.3
1710.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0 to 100 [mm]
0 to 300 [mm]
20
20
20
20
20
EMERGENCY STOP
(GROSS POSITIONING ERROR)
X
Y
Z
IV
V
1720
1720.0
1720.1
1720.2
1720.3
1720.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0 to 100 [mm]
0 to 300 [mm]
30
30
30
30
30
1. block of Kv factors
for the trailing mode
X
Y
Z
IV
V
1810.0
1810.1
1810.2
1810.3
1810.4
0.1 to 10
1
1
1
1
1
2. block of Kv factors for the
trailing mode
M105: enable
M106: disable
X
Y
Z
IV
V
1815.0
1815.1
1815.2
1815.3
1815.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.1 to 10
1
1
1
1
1