HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 171
Display and Programming
Function
MP
A
B
C
D
E
F
Input
AE-6
No.
Bit
Entry Value
Protecting file types
(for selection, table of contents and
external data transfer)
HEIDENHAIN programs
ISO programs
Tool tables
Datum tables
Pallet tables
ASCII (text) files
PLC HELP files
Measuring point tables
(.H)
(.I)
(.T)
(.D)
(.P)
(.A)
(.HLP)
(.PNT)
7224.1*
0
1
2
3
4
5
6
7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
08
08
0 =
no file type protected
+ 1 =
protected
+ 2=
protected
+ 4=
protected
+ 8=
protected
+ 16=
protected
+ 32=
protected
+ 64=
protected
+ 128=
protected
% 00000000
(0)
Preset size
Pallet table
Datum table
(.P)
(.D)
7226.0*
7226.1*
05
05
08
08
0 to 255 =
number of reserved entries
(can be expanded via soft key)
10
10
Size of NC memory for
DNC mode
Minimum
Maximum
7228.0
7228.1
-
-
-
-
-
-
-
-
08
08
1 to 1024 [kBytes]
1 to 1024 [kBytes
1
10
Switching over the dialog
language
7230*
0 =
first dialog language
1 =
second dialog language (English)
0
* accessible via code number 123
08.05.95
10.2
40