86

31-O

SERVICE MANUAL TNC 4071415

01.09.1995

Page

8

Error Location

Error Cause

Position (Servo Lag) Monitoring
Operation with feed precontrol: position monitoring range ex-

ceeded (range determined in MP

Operation with servo lag: servo lag monitoring range ex-

ceeded (determined in MP

Monitoring of the Analog Voltage Limit
The nominal voltage calculated by the control has reached its

limit of 10 V

with feed

Movement Monitoring

The voltage difference calculated by the control has reached

the limit programmed in the machine parameter MP 1140.x.

Standstill Monitoring
The deviation from the nominal position of an axis in

standstill has exceeded the value programmed in the
machine parameter MP

Monitoring of the Offset Voltage
The offset voltage limit of 100

has been reached during

an automatic offset adjustment with MP 1220.

(see section 16.5)

CPU number

1 main processor

2 geometry processor
3 CLP processor

When the error message “GROSS POSITIONING ERROR” is displayed, the error may be located in any

element of the closed loop.

e.g.

Error in control

CLP board)

Excessive offset voltage at the servo amplifier
Incorrect speed adjustment at the servo amplifier
Monitoring function of servo amplifier has responded

(e.g. monitoring of current intensity)

Electrical defect at the servo amplifier

Mechanical error (bearing, spindle, guides)
Excessive mechanical forces on a drive