Matrix Data Example

The following describes a typical example procedure for sending commands
that set up the data analyzer for sampling of distance data with a distance
sensor.

1. Input the following matrix data on the CFX-9800G.

1

Channel clear

0

1

Command 1

4

Channel: SONIC

2

Unit: meters

3

Command 3

0.5

Sampling duration: 0.5 second

20

Number of samples: 20

1

Absolute time recording: On

2. Now perform the steps under “To send matrix data from the CFX-9800G”

above to send the matrix to the data analyzer. Note that the final matrix
data sent to the data analyzer before the start of sampling must be Com-
mand 3 (SAMPLE AND TRIGGER SETUP).

3. Press the data analyzer’s [TRIGGER] key to start data sampling.

4. The DONE indicator appears on the display when data sampling is com-

plete. See “Transferring Data to the CFX-9800G” for details on transfer-
ring sampled data from the data analyzer to the CFX-9800G.