DG1000Z Programming Guide

*TRG

Syntax

*TRG

Description

Trigger a sweep or burst.

Explanation

 You can only trigger the sweep or burst via the remote interface when the

sweep or burst function is currently enabled and the trigger source is set to

manual (use the

[:SOURce[<n>]]:SWEep:TRIGger:SOURce

or

[:SOURce[<n>]]:BURSt:TRIGger:SOURce

command).

 You can also send the

[:SOURce[<n>]]:SWEep:TRIGger[:IMMediate]

or

[:SOURce[<n>]]:BURSt:TRIGger[:IMMediate]

command to trigger a sweep or

burst when the sweep or burst function is currently enabled and the trigger

source is set to manual.

Related

Commands

[:SOURce[<n>]]:BURSt:TRIGger[:IMMediate]

[:SOURce[<n>]]:BURSt:TRIGger:SOURce
[:SOURce[<n>]]:SWEep:TRIGger[:IMMediate]
[:SOURce[<n>]]:SWEep:TRIGger:SOURce

*WAI

Syntax

*WAI

Description

Execute any other command via the interface after all the pending operations are

completed.

Explanation

This command is only applicable to the triggered sweep mode or triggered burst

mode, and is used to ensure synchronization.