Chapter 6 Display Dictionary

INTO T SITE JAM

The handler has tried to load a device into the test site, but the device has failed to arrive there. Manually
clear the jammed device and the handler will automatically restart.

Or press the [Clear] button to "thump" the test rail (clears many jams common to this area.)

Or press [Enter] to try the load cycle again.
NOTE: This may cause DOUBLE PART ERR messages to appear.

ISSUE NEW START

The handler has been instructed by the operator to send a new start test pulse to the tester/PC.

JOG DOWN

The plunger has moved down one step, about .003"

JOG LEFT

The shuttle/octoloader has moved one step left, about .006".

JOG OCTOLOADER

This message is displayed during power up while the handler is self-aligning the octoloader. No action
required.

JOG RIGHT

The shuttle/octoloader has moved one step right, about .006".

JOG SHUTTLE

This message is displayed during power up while the handler is self-aligning the shuttle. No action
required.

JOG UP

The plunger has moved up one step, about .003"

LOAD DEFAULT NO

Exits routine without reloading the EPROM default settings into the handler’s RAM.

[Enter] will exit with no changes.

[SET UP] will toggle back to LOAD DEFAULTS YS.

LOAD DEFAULT YS

Allows the operator to reload the handler's RAM with settings stored in the handler's EPROM.

[Enter] will load defaults from EPROM to RAM.

[SET UP] will toggle back to LOAD DEFAULTS NO.