Rs-232 interfaces, Rs-232 port options, Rs-232 i – Extron electronic 3000B User Manual
Page 57: Nterfaces, Rs-232 port options: -15, Exatron 3000b, Rs-232
Exatron 3000B
www.exatron.com
3-15
Chapter 3 Interface Info
RS-232 Interfaces
E
XATRON
S
UPER
~ E
XATRON
RS-232 ~ H P RS-232 ~ P
ROGRAMMER
RS-232
RS-232 Port Options:
Listed below are addresses in the handler's battery backed-up RAM which may be edited to fine tune
the handler for your specific programmer/tester and sorting requirements. These addresses are not
part of the standard power-up selections and may be modified only by “Changing The RAM,” as
described in the Handler Set-Up Chapter of this manual.
B
AUD
R
ATE
009A __
This address stores the baud rate setting for the RS-232 serial port. The RS-232
port uses the 25 pin RS-232 connector on the side of the handler.
009A
06
19200 Baud
009A
0C
9600 Baud [Default setting]
009A
18
4800 Baud
009A
30
2400 Baud
009A
60
1200 Baud
009A
C0
600 Baud
009A
80 300
Baud
D
ATA
F
ORMAT
009B
__
This address stores the data format setting for the RS-232 port.
009B
02
No parity
7 Data 1 Stop
009B
2A
Stick one
7 Data 1 Stop
009B
3A
Stick zero
7 Data 1 Stop
009B
1A
Even parity
7 Data 1 Stop
009B
0A
Odd parity
7 Data 1 Stop
009B
06
No parity
7 Data 2 Stop
009B
2E
Stick one
7 Data 2 Stop
009B
3E
Stick zero
7 Data 2 Stop
009B
1E
Even parity
7 Data 2 Stop
009B
0E
Odd parity
7 Data 2 Stop
009B
03
No parity
8 Data 1 Stop [Default setting]
009B
2B
Stick one
8 Data 1 Stop
009B
3B
Stick zero
8 Data 1 Stop
009B
1B
Even parity
8 Data 1 Stop
009B
0B
Odd parity
8 Data 1 Stop
009B
07
No parity
8 Data 2 Stop
009B
2F
Stick one
8 Data 2 Stop
009B
3F
Stick zero
8 Data 2 Stop
009B
1F
Even parity
8 Data 2 Stop
009B
0F
Odd parity
8 Data 2 Stop