6-21
Chapter 6 Display Dictionary
10. You may press the [7] key. This key only operates when the PROGRAM RS-232 interface has been
chosen. The handler will display SET P/V/L MODE?
Select one of the following operations:
[1] = PROGRAM DEVICE? Sets the handler to bit check and Program the device in the
handler.
[2] = VERIFY DEVICE ? Sets the handler to Verify the device in the handler.
[3] = LOAD DEVICE ? Sets the handler to Load data from the device to the programmer
RAM.
[Enter] Sets your selection.
[Clear] Resets to the top of the handler's SET P/V/L MODE?
11. You may press the [8] key. The handler will now display STOP ON FAIL ? Choose to make the
handler either stop on fail or continue operation. If STOP ON FAIL YS is chosen, then the handler will
stop operation at every DUT test failure the handler receives.
The handler provides many helpful troubleshooting operations while the DUT is in the contacts and
STOP ON FAIL is displayed by the handler:
[1] = STOP ON FAIL YS. Stop on fail is now ON.
[2] = STOP ON FAIL NO. Stop on fail is now OFF.
[Enter] Sets your selection.
[Clear] Resets to the top of the handler's STOP ON FAIL ? loop.
SUM CHECK = _ _ _ _
Four alphanumeric characters will be displayed following the message shown above. The handler is using
the PROGRAM RS-232 interface. The handler has just completed a successful data load of a master
device into the programmer’s RAM. The handler is displaying the sum check reported back from the
programmer.
SUM CHECK ERROR
The handler is using the PROGRAM RS-232 interface. The handler has asked the programmer for the
current sum check, and an error was detected. Check the programmer set-up. You may press [Enter] to
skip past this error and try again. Or you may press [Clear] to flush the handler of all devices.
T SITE OUT JAM
The handler is attempting to move a device out of the test site and into the shuttle. The device has failed
to arrive.
1. Inspect the output of the plunger for a jammed device. If you manually clear the jam, the
handler will automatically restart.
2. Press
the
[Clear] button to flush the handler.
3. Press
the
[MANUAL] button to stop the operation and enter Manual Mode. Verify the plunger
upper stop setting by running the Self Adjust Z procedure as described in Chapter 5 of this
manual.