5.3 AC Input Voltage Specification

STATUS

Required

The power supply must operate within all specified limits over the following input voltage range. Harmonic
distortion of up to 10% THD must not cause the power supply to go out of specified limits. The power supply shall
operate properly at 85 VAC input voltage to guarantee proper design margins.

Table 2: AC Input Rating

PARAMETER

MIN

RATED

MAX

350W Max

Rated Input

Current

480W Max

Rated Input

Current

Voltage (110)

90 V

rms

100-127

V

rms

140 V

rms

5.5 A

rms

1

7.0 A

rms

1

Voltage (220) 180 V

rms

200-240

V

rms

264 V

rms

2.3 A

rms

1

3.5 A

rms

1

Frequency

47 Hz

63 Hz

1

Maximum rated input current is measured at 100 VAC and 200 VAC.

5.4 Efficiency

STATUS

Required

The power supply shall have a minimum efficiency shown in the table below for the different power ratings. The
power dissipated within the sub-system shall be kept to less than 150W. The sub-system shall meet the minimum
efficiency at 100VAC and maximum output load.

Table 3: Efficiency

Output

Power

Minimum

Efficiency

350W

70%

480W

77%

Advertising