SSI

ERP2U Power Supply Design Guide, V1.0

- 18 -

6.6 Dynamic Loading

STATUS

Required

The output voltages shall remain within the limits specified in Table 13 for the step loading and within the limits
specified in Table 15 for the capacitive loading. The load transient repetition rate shall be tested between 50 Hz
and 5 kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test specification.
The

step load may occur anywhere within the MIN load to the MAX load shown in Table 11.

Table 15: Transient Load Requirements

Output

∆ Step Load Size Load Slew

Rate

Capacitive Load

+3.3 V

30% of max load

0.5 A/

µ

s

1,000

µ

F

+5 V

30% of max load

0.5 A/

µ

s

1,000

µ

F

12V1+12V2+(12V3)

65% of max load

0.5 A/

µ

s

1,000

µ

F

+5 VSB

25% of max load

0.5 A/

µ

s

1

µ

F

6.7 Capacitive Loading

STATUS

Required

The power supply shall be stable and meet all requirements, except dynamic loading requirements, with the
following capacitive loading ranges.

Note: Up to 10,000

µ

F of the +12V capacitive loading may be on the +12V1 output.

Table 16: Capacitve Loading Conditions

Output

MIN

MAX

Units

+3.3 V

10

12,000

µ

F

+5 V

10

12,000

µ

F

+12 V

10

11,000

µ

F

-12 V

1

350

µ

F

+5 VSB

1

350

µ

F

6.8 Ripple / Noise

STATUS

Required

The maximum allowed ripple/noise output of the power supply is defined in Table 17. This is measured over a
bandwidth of 0 Hz to 20 MHz at the power supply output connectors. A 10

µ

F tantalum capacitor in parallel with a

0.1

µ

F ceramic capacitor are placed at the point of measurement.