ERP2U Power Supply Design Guide, V1.0

- 27 -

8.2 PWOK (Power OK)

STATUS

Required

PWOK is a power OK signal and will be pulled HIGH by the power supply to indicate that all the outputs are within
the regulation limits of the power supply. When any output voltage falls below regulation limits or when AC power
has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PWOK will
be deasserted to a LOW state. See Figure 3 for a representation of the timing characteristics of PWOK. The
start of the PWOK delay time shall be inhibited as long as any power supply output is in current limit.

Table 24: PWOK Signal Characteristics

Signal Type

Open collector/drain output from power supply. Pull-up
to VSB located in power supply.

PWOK = High

Power OK

PWOK = Low

Power Not OK

MIN

MAX

Logic level low voltage, Isink = 4 mA

0 V

0.4 V

Logic level high voltage, Isource=200

µA

2.4 V

5.25 V

Sink current, PWOK = low

4 mA

Source current, PWOK = high

2 mA

PWOK delay: T

pwok_on

200 ms

1000 ms

PWOK rise and fall time

100

µ

s

Power down delay: T

pwok_off

1 ms

200 ms