4.5

Computer Diagnostics

TracVision G8 has been designed to provide diagnostic readouts
viewed on a PC having an RS-232 serial communication port. If
you are unable to isolate a system problem, set up for computer
diagnostics as described below. System problems will most likely
be found somewhere through the diagnostic readouts.

The diagnostics procedure requires Windows Hyperterminal (or
other terminal emulation software, such as PROCOMM). Use the
settings appropriate to your application.

1. Connect one end of the PC data cable to

the DB9 maintenance port connector on the rear of
the MCU. Connect the other end to the serial port
on your PC (a 9-pin/25-pin connector adapter may
be needed for some PCs).

2. Open the terminal emulation software and

establish the following settings:

• 9600 baud

• no parity

• 8 data bits

• 1 start bit

• 1 stop bit

• no flow control

3. Apply power to the TracVision G8 system and

allow the system to complete full initialization.
Data should be scrolling on the PC display to
identify any system problems detected. If no data
is seen, recheck your connections and the terminal
software setup.

54-0198

88

TracVision G8 Owner’s Manual - Guide to Technical Information

Figure 4-3

MCU Maintenance Port

Maintenance Port