Registry resource type, Alarm code: 1, Event id: ela-registry01 – Lucent Technologies INTUITY Messaging Solutions Enhanced-List Application 585-310-575 User Manual

Page 71: Alarm code: 2, Event id: ela-registry02

Advertising
background image

REGISTRY Resource Type

Issue 1 July 1997

61

2. Verify/administer the screen information, as required.

3. Repeat for the delivery trusted server.

4. Enter

ch imapi

and verify/administer as required.

5. When complete, enter the correct information in the Set Up Enhanced-List

System Data window.

REGISTRY Resource Type

Alarm Code: 1

Event ID: ELA-registry01

Alarm Level:

Warning

Description:

E-list registry lost, re-enter or restore. The ELA software has

detected that registry database has disappeared.

Repair Action:

1. Re-administer the registry:

a. Go to the Administer Enhanced-Lists window.

b. Use (F4) NEW E-LIST to re-enter the name of each Enhanced List,

one at a time. (The individual members do not need to be
re-entered.)

See

Lucent I

NTUITY

™ Messaging Solutions Release 4

Administration, 585-310-564 for more detailed procedures.

2. If the alarm persists, restore system data from the nightly backup. See

Chapter 3, “Common System Procedures,” in your maintenance book for
instructions about restoring data. If you would prefer to have assistance
with this restore, contact your remote maintenance center.

Alarm Code: 2

Event ID: ELA-registry02

Alarm Level:

Minor

Description:

Unable to write updated E-list registry.

Repair Action:

This alarm requires intervention from the remote maintenance center.

Advertising