Figure 13.1 alarm menu (8/16-channel), From the main menu, click . the alarm menu opens, Click and edit the following – LOREX Technology NETWORK READY H.264 HIGH PERFORMANCE DIGITAL VIDEO SURVEILLANCE RECORDER LH300 Series User Manual

Page 50: Figure 13.2 alarm input & output menu, Figure 13.4 alarm-out setup menu, 8/16-channel

Advertising
background image

36

Using the Main Menu

8/16-channel

To configure the alarm settings:

1. From the Main Menu, click

. The

Alarm menu opens.

2. Click and edit the following:

Video Loss Alarm: Click under each

camera and select either O to enable
the VLoss alarm, or

X

to disable it. If

enabled, the system will sound an
alarm whenever one of the connected
channels incurs a loss of video.

Motion Enable: Click under each

camera and select O to enable motion
detection or select

X

to disable it. If

enabled, the camera can record in
specific recording parameters when it
detects motion.

NOTE: With Motion Detection enabled,
the text, "Motion" appears on-screen
(full-screen and quad split-screen)
whenever a motion event is triggered.

Buzzer: Select O to enable the system

to beep when an alarm is triggered or
motion is detected; select

X

to disable

it.

Key Buzzer: Select O to enable the

system beep when you click the mouse,

press the buttons on the remote/front
panel. Select

X

to disable the beep.

Alarm Input & Output: Click to open the

Alarm Input & Output menu.

• Alarm-In Type: Select OFF/ NO
(normally open) / NC (normally closed)
to select alarm type.

• Alarm-In Setup: Click to open the
Alarm-In Setup menu. Click to assign
channels to up to four alarms.

Alarm-Out Setup: Click to open the
Alarm-Out Setup menu. Click to assign
an Event notification (Motion, VLoss,
Alarm) to an Alarm-Out notification
(Buzzer, Full-Screen, Label, Alarm Out
1).

VLoss Response Time: Select the time
(in seconds) for the system to record
prior to a triggered event: 0, 3, 5, 10, 30,
60, 120, 180, or Infinite

Figure 13.1 Alarm menu (8/16-channel)

Figure 13.2 Alarm Input & Output menu

Figure 13.3 Alarm-In Setup menu (8/16-channel

only

)

Figure 13.4 Alarm-Out Setup menu

Advertising