LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 55 of 221

Revision A (Sep 2007)

Index (Printer) Pulse Output (Pins 22-23)

Also referred to as a Once-Per-Rev (OPR) pulse, this output can be configured
to output pulses at specified length intervals. This output can be used to
control a cutter or a printer.

For example, if you use LaserTrak to set the “Index Pulse Every X m” setting
to 10m, the gauge would output a single pulse every 10m of product
movement.

The Index pulse will only trigger when the line is moving in the (+) direction. If
the Index Pulse triggers at a certain length, and then the line backs up and
passes that point again, the Index Pulse will not be repeated.

The Index Pulse is asserted for a configurable amount of time. This time can
be configured by changing the Index Pulse Length setting. See the

Configuration Settings

section for details.

Example:

Index Pulse Length = 100ms

Index Pulse Interval = 10m

Index Pulse Output Example

The Index Pulse Output can be reconfigured to output several different status
outputs using the Auxiliary Digital Output Configuration setting. See the

Configuration Settings

section for details.

+24V

DC

Power Input (Pins 24-25) and Power Grounds (Pins 12-13)

Two Power Input pins and two Power Ground pins are supplied to reduce
voltage drop in long cables. Please see the Connecting Power to the Gauge
section and Appendix D for details concerning power wiring. Pins 24 and 25
and pins 12 and 13 are internally connected in the LS8000-3.