The feed velocity during a move becomes the commanded velocity multiplied by the velocity override value.
If the velocity override value is changed during a move, the moving part is accelerated at the same acceleration
profile and acceleration as the normal acceleration time when the velocity override value is increased. In the
same way, the moving part is decelerated at the same deceleration profile and deceleration as the normal
deceleration time when the velocity override value is decreased.

[Acceleration: s-shaped, deceleration: constant acceleration]

Waiting for trigger

500ms/div

NORM:2kS/s

150%

100%

0%

Waiting for trigger

500ms/div

NORM:2kS/s

150%

100%

0%

[Related parameters]

#3

Selecting the type of cam profile move

#4

Selecting the acceleration type

#5

Selecting the deceleration type

#7

Acceleration time during a trapezoidal move

#8

Deceleration time during a trapezoidal move