10.7 STANDALONE TEST MODES

Test modes are specified by address location and may be used to
debug network connections or provide standalone color changing
options without the need for a DMX controller. Colours are assuming
LED loads are connected in RGB configuration as shown on page 15,
section 9.4)

ADDRESS

FUNCTION/SEQUENCE

000

NO FUNCTION

001-512

DMX ADDRESS MODE

513

GREEN ON

514

RED ON

515

BLUE ON

516

BLUE & RED ON (MAGENTA)

517

BLUE & GREEN ON (CYAN)

518

GREEN & RED ON (YELLOW)

519

ALL OUTPUTS AT 5%

520

EACH COLOR RAMPING UP AND DOWN INDIVIDUALLY – SPEED 1

521

EACH COLOR RAMPING UP AND DOWN INDIVIDUALLY – SPEED 2

522

CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) – SPEED 1

523

CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) – SPEED 2

524

CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) – SPEED 3

525

CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) – SPEED 4

526

CROSS FADE BETWEEN COLOURS (RED UP, GREEN UP, RED
DOWN, BLUE UP ETC.) – SPEED 5

530

ALL ON

531

CHANNEL 1 ON

532

CHANNEL 2 ON

533

CHANNEL 3 ON

534

CHANNEL 4 ON

535

CHANNEL 5 ON

536

CHANNEL 6 ON

537

CHANNEL 7 ON

538

CHANNEL 8 ON

539

CHANNEL 9 ON

540

CHANNEL 10 ON

541

CHANNEL 11 ON

542

CHANNEL 12 ON

Document: 66APPMAN-PC Rev: C

11 of 28

8.0 OUTPUT CHANNEL REQUIREMENTS

8.1 Electrical Output Specifications:

Output specifications are defined in table 2 on page 4 of this manual.

Actual output currents and maximum voltages are dependant on the

model configuration, see table 6, 8 or table 10 at the beginning of this

manual for configuration options.


8.2 Output Wiring Requirements

WARNING: All output channels are isolated from each other and

require a separate 2 wire twisted pair for each output LED load.

When connecting LED loads to output cables observe ‘+’ and ‘-‘ po-

larity connections to prevent damage to loads. To reduce risk of fire or
electric shock, do not interconnect output terminations.

A common anode or cathode wiring method for multiple LED

loads cannot be used for the TRINITY PC.

All output wires should be connected to their respective LED loads

before power up to prevent inadvertent shorting of outputs. Shorting of
outputs (+ve to –ve only) will result in a hiccup mode of operation with
automatic recovery after removal of a short.

Output Class 2 circuit wiring must comply with NEC Article 725 wir-

ing methods or to CEC section 16-210 wiring methods.

Output cabling should be overall shielded cables with twisted pair

conductors (18 AWG ) to minimize cross talk between channels and mini-
mize Electromagnetic Interference (EMI).

Consult your local Electrical Safety Authority for acceptability in

your end use application.

With appropriate cabling, the TRINITY PC may be remote mounted

up to 150 feet (45 meters) from the LED loads.

7.0 INPUT REQUIREMENTS
7.1 Electrical Input Specifications:

Input specifications are defined in table 1 on page 4 of this

CAUTION

RISK OF DAMAGE:

DO NOT connect input of power unit to a phase cut dimmer or dim-
ming panel. It will cause internal damage to the power unit