11.0

0-10 Vdc ANALOG INTERFACE


11.1 LED Status Indicator

Power Indicator-Green LED will turn off if no power is detected.

Dimming-Green LED will flash when output master is at full on (100%
light intensity). Green LED will vary in intensity proportionally to mas-
ter 0-10 Vdc control signal for intensity levels less than 100%.

Zone #4
Output Channels
10,11,12

Zone #1
Output
Channels 1,2,3

Zone # 3
Output
Channels 7,8,9

Zone #2
Output
Channels 4,5,6

Master & Zone
Dimming Inter-
face Connections

P

ow

e

r I

nd

ic

a

to

r

Ana

log D

im

m

ing

Acti

ve

Document: 66APPMAN-PC Rev: C

9 of 28

5.0

INSTALLATION GUIDELINES AND SAFETY REQUIRE-
MENTS


This power unit has been evaluated to the requirements for:
UL8750 1

st

Edition: LED Light Equipment for Use in Lighting Products

5.1 ELECTRICAL REQUIREMENTS

This power unit is intended for connection to a 20A branch circuit
and an appropriate disconnect device shall be provided as part of
the building installation.

The socket outlet shall be installed near the equipment and shall be
easily accessible.

All secondary output circuits are SELV, limited power source (LPS)
and Class 2.

5.2 MOUNTING AND ENVIRONMENTAL REQUIRE-

MENTS

This power unit is limited to fixed non-plenum locations.

This power unit is rated for dry locations only.

The power unit is intended for use in a nonconductive pollution
environment only.

This power unit is rated for operation at a maximum ambient tem-
perature of 40 ºC.

Allow sufficient spacing around heat sink extrusion fins for convec-
tion air flow.

Do not block ventilation openings.

WARNING

RISK OF FIRE OR ELECTRIC SHOCK:

Do not modify, remove, or replace the input power cord

Do not remove enclosure cover. No serviceable parts inside

Do not connect Analog Interface to class 1 circuits

Follow all NEC/CEC, local electrical code requirements for installation

To reduce the risk of fire or electric shock, do not interconnect output
terminations

Advertising