LumaStream Trinity Power Cord User Manual

Page 8

Advertising
background image

Document: 66APPMAN-PC Rev: C

8 of 28

2.0

SCOPE


The TRINITY PC is intended for powering and dimming Class 2 low voltage
lighting systems.

It is intended for installation in non-plenum locations in accordance with
required local, state, provincial, country and NEC/CEC regulations.

This manual provides general installation, use and application guidelines for
the TRINITY PC. It should be read in conjunction with product datasheets.
Data sheets may be downloaded at

www.powervector.com

.


While every effort has been made to ensure the accuracy of the contents of
this manual, LumaStream cannot accept any liability for errors contained
herein. Specifications are subject to change without prior notice.

3.0

OWNER/USER RESPONSIBILITIES


It is the responsibility of the contractor, installer, buyer, owner and user to
install, maintain, and operate the TRINITY PC in accordance with all
applicable laws, regulations and local Electrical Safety Authority
requirements. There are no field serviceable parts within power unit.

4.0

EMC COMPLIANCE


This device complies with Part 15 of the FCC Rules. Operation is subject to
the following conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.

This Class A digital apparatus complies with Canadian ICES-003
requirements.

Warning: This is a Class A product. In a domestic environment this product
may cause radio interference, in which case the user may be required to take
adequate measures.


Document: 66APPMAN-PC Rev: C

21 of 28

11.2 Output Zone/Channel Connections Table

Either 6, 9, or 12 output channel options are available for driving and
dimming LEDs. Channels are assigned to zones as shown in the following
tables. A 6 or 9 channel option will provide 3 zones for dimming and a 12
channel option will provide 4 zones for dimming.

Zone Number

Output Channel

Belden/Alpha or Equivalent Wire

Color/Polarity

1

1

WHT + / BLK -

1

2

RED

+ / BLK -

1

3

GREEN

+ / BLK -

2

4

WHT + / BLK -

2

5

RED

+ / BLK -

2

6

GREEN

+ / BLK -

3

7

WHT + / BLK -

3

8

RED

+ / BLK -

3

9

GREEN

+ / BLK -

4

10

WHT + / BLK -

4

11

RED

+ / BLK -

4

12

GREEN

+ / BLK -

Zone Number

Output Channel

Belden/Alpha or Equivalent Wire

Color/Polarity

1

1

WHT + /

GREEN

-

1

2

RED

+ / BLK -

2

3

WHT + /

GREEN

-

2

4

RED

+ / BLK -

3

5

WHT + /

GREEN

-

3

6

RED

+ / BLK -

9/12 Channel - Zone Connection Table

6 Channel - Zone Connection Table

Advertising