LumaStream Trinity Power Cord User Manual

Page 5

Advertising
background image

Document: 66APPMAN-PC Rev: C

24 of 28

Note: This wiring configuration provides simultaneous dimming control for
all zones 1,2,3,4 with a commercial dimming interface comprising (1)
0-10Vdc control signal.

11.6 INSTALLATION EXAMPLES

(1) TRINITY PC ANALOG, (1) COMMERCIAL DIMMING PANEL
WITH (1) 0-10VDC ANALOG CONTROL SIGNAL

Document: 66APPMAN-PC Rev: C

5 of 28

Table 4

Environmental Specifications

Location Rating

Dry

Operating Ambient Temperature

-20ºC to +40ºC

Cold Start Temperature

-20ºC

Storage Ambient Temperature

-40ºC to 80ºC

Relative Humidity

5% to 95% noncondensing

MTBF (MIL HDBK-217F)
(12 channel)

>60,000 hours @ 40ºC
>97,000 hours @ 25ºC

Table 5

Protection

Output Protection

Over voltage, over current, short circuit protection

Over Temperature
Protection

Power supply will shut down when external ambient
temperature exceeds 43ºC or case temperature
reaches 85ºC nominal

Output Interconnection
Protection

Hiccup Mode with automatic recovery upon re-
moval of short. Only applies to +ve to –ve intercon-
nections.

Advertising