LumaStream Trinity Power Cord User Manual

Page 4

Advertising
background image

Document: 66APPMAN-PC Rev: C

4 of 28

Table 1

Input Specifications

Rated Input Voltage
And Frequency

115 to 125

47-63

Vac
Hz

Rated Input Current

A

2.4-2.2

Power Factor
EN61000-3-2

@ 115 Vac, 100% load

0.97

W/VA
min

Input Current Total
Harmonic Distortion

@ 115 Vac 100% load

13

% max

Table 2

Output Specifications

Rated Output
Power

66-xx-yyyy-zzz-PC models
70-xx-yyyy-zzz-PC models

@ 40 °C ambient



243
226

W max

Efficiency

100% load @
115 Vac input

87

%

Turn on delay

Time required for
stabilization of all

Outputs

2

sec

typical

Output Current
Tolerance

+/-5 % of nominal

Table 3

Safety and EMI/EMC Specifications

Agency Approvals

UL 8750 class 2 outputs

Conducted & Radiated Emissions

ICES-003
FCC Title 47, Part 15 Class A

EMC

EN61547-General Lighting

1.1 SPECIFICATIONS

Document: 66APPMAN-PC Rev: C

25 of 28

(1)TRINITY PC ANALOG, (1) COMMERCIAL DIMMING PANEL
WITH (4) 0-10VDC ANALOG CONTROL SIGNALS

Note: This wiring configuration provides independent dimming control
for each zone 1,2,3,4 with a commercial dimming interface comprising (4)
0-10Vdc control signals.

Advertising