HP StorageWorks 2.128 SAN Director Switch User Manual

Page 154

Advertising
background image

154 Troubleshooting

For example:

• A high number of errors relative to the frames transmitted and frames received can indicate a

marginal link (see

Correcting marginal links

” on page 159 for additional information).

• A steadily increasing number of errors can indicate a problem. Track errors by sampling the port

errors every five or ten minutes.

5.

Issue the

portFlagsShow

command and then check to see how a port has logged in and where a

login failed (if a failure occurred).
For example:

6.

Issue the

portLogDumpPort portid

command, where

portID

is the port number, and then view

the device to switch communication.

sw094135:admin> porterrshow

frames enc crc too too bad enc disc link loss loss frjt fbsy

tx rx in err shrt long eof out c3 fail sync sig

=====================================================================

0: 38 75 0 0 0 0 0 0 0 9 11 0 0 0

1: 110 73 0 0 0 0 0 0 0 9 11 0 0 0

2: 0 0 0 0 0 0 0 38 0 4 0 2 0 0

3: 0 0 0 0 0 0 0 0 0 4 1 2 0 0

4: 59m 102 0 0 0 0 0 0 0 4 0 0 0 0

5: 59m 103 0 0 0 0 0 0 0 3 0 0 0 0

6: 0 0 0 0 0 0 0 21 0 3 0 0 0 0

7: 0 0 0 0 0 0 0 58 0 3 0 0 0 0

8: 81 19k 0 0 0 0 0 3.0m 0 5 43 0 0 0

9: 0 0 0 0 0 0 0 29 0 3 0 0 0 0

10: 12m 68m 0 0 0 0 0 13 43m 8 1 1 0 0

11: 30m 33m 0 0 0 0 0 0 0 8 1 1 0 0

12: 89 25k 0 0 0 0 0 2.9m 0 7 43 0 0 0

13: 0 0 0 0 0 0 0 0 0 3 0 0 0 0

14: 29m 82m 0 0 0 0 0 0 1.2m 4 1 1 0 0

15: 29m 81m 0 0 0 0 0 0 1.1m 4 1 1 0 0

sw094135:admin> portflagsshow

Port SNMP Physical Flags

-------------------------------

0: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

1: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

2: Offline No_Light PRESENT U_PORT LED

3: Offline No_Light PRESENT U_PORT LED

4: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

5: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

6: Offline No_Light PRESENT U_PORT LED

7: Offline No_Light PRESENT U_PORT LED

8: Online In_Sync PRESENT ACTIVE F_PORT L_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT

9: Offline No_Light PRESENT U_PORT LED

10: Online In_Sync PRESENT ACTIVE G_PORT U_PORT LOGIN LED

11: Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT

12: Online In_Sync PRESENT ACTIVE F_PORT L_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT

13: Offline No_Module PRESENT U_PORT LED

14: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

15: Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED

Advertising