HP StorageWorks 2.128 SAN Director Switch User Manual

Page 208

Advertising
background image

208 Administering advanced performance monitoring

The command format is:

perfmonitorshow --class monitor_class [slotnumber/]portnumber [interval]

The following example displays an EE monitor on a port at an interval of every 6 seconds:

The following example displays EE monitors on a port:

where:

monitor_class

Specifies the monitor class, which can be

EE

,

FLT

(filter-based), or

ISL

. The

--class

monitor_class

operand is required.

slotnumber

Specifies the slot number for a Core Switch 2/64, SAN Director 2/128, or

4/256 SAN Director. For all other switches, this operand is not required. The

slot number must be followed by a slash ( / ) and the port number, so that

each port is represented by both slot number (1 through 4 or 7 through 10)

and port number (0 through 15).
The HP StorageWorks director has a total of 10 slots. Slot numbers 5 and 6

are CP blades; slots 1 through 4 and 7 through 10 are port blades. For

16-port blades, there are 16 ports, counted from the bottom, numbered 0 to

15. For 32-port blades, there are 32 ports numbered 0 to 31.

portnumber

Specifies a port number. Valid values for port number vary, depending on the

switch type. This operand is required.

interval

Specifies an interval in seconds. The interval must be greater than or equal to

five seconds. For EE monitoring, the Tx and Rx counts are measured in bytes.

This operand is optional.

switch:admin> perfMonitorShow --class EE 4/5 6

perfmonitorshow 53, 6: Tx/Rx are # of bytes and crc is # of crc errors

0 1 2 3 4

------------- ------------- ------------- ------------- -------------

crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx

============= ============= ============= ============= =============

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 53m 4.9m 0 53m 4.9m 0 53m 4.9m 0 53m 4.9m 0 53m 0

0 53m 4.4m 0 53m 4.4m 0 53m 4.4m 0 53m 4.4m 0 53m 0

0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 0

0 53m 4.6m 0 53m 4.6m 0 53m 4.6m 0 53m 4.6m 0 53m 0

0 53m 5.0m 0 53m 5.0m 0 53m 5.0m 0 53m 5.0m 0 53m 0

0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 0

0 53m 4.5m 0 53m 4.5m 0 53m 4.5m 0 53m 4.5m 0 53m 0

0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 0

0 52m 5.0m 0 52m 5.0m 0 52m 5.0m 0 52m 5.0m 0 52m 0

0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 0

0 52m 4.6m 0 52m 4.6m 0 52m 4.6m 0 52m 4.6m 0 52m 0

switch:admin> perfMonitorShow --class EE 4/5
There are 7 end-to-end monitor(s) defined on port 53.
KEY SID DID OWNER_APP OWNER_IP_ADDR TX_COUNT RX_COUNT CRC_COUNT
------------------------------------------------------------------------------------------------------------
0 0x58e0f 0x1182ef TELNET N/A 0x0000000000000000 0x0000000000000000 0x0000000000000000

0 0x21300 0x21dda TELNET N/A 0x00000004d0ba9915 0x0000000067229e65 0x0000000000000000

1 0x21300 0x21ddc TELNET N/A 0x00000004d0baa754 0x0000000067229e65 0x0000000000000000
2 0x21300 0x21de0 TELNET N/A 0x00000004d0bab3a5 0x0000000067229e87 0x0000000000000000
3 0x21300 0x21de1 TELNET N/A 0x00000004d0bac1e4 0x0000000067229e87 0x0000000000000000
4 0x21300 0x21de2 TELNET N/A 0x00000004d0bad086 0x0000000067229e87 0x0000000000000000
5 0x11000 0x21fd6 WEB_TOOLS 192.168.169.40 0x00000004d0bade54 0x0000000067229e87 0x0000000000000000
6 0x11000 0x21fe0 WEB_TOOLS 192.168.169.40 0x00000004d0baed41 0x0000000067229e98 0x0000000000000000

Advertising