Initiator management – HP VMA-series Memory Arrays User Manual

Page 209

Advertising
background image

AM456-9007B Rev 02

HP VMA SAN Gateway Installation and User Guide

209

To assign a user-defined LUN ID to exported LUNs, select the Value
option button and enter a value in the space. User-defined LUN IDs may
make it easier differentiate between LUNs. If you do assign user-defined
LUN ID, HP recommends that you specify a number below 255 as some
operating systems (for example, Windows) will only discover LUN IDs
between 0 and 254.

To automatically assign an ID to the exported LUNs, select the Auto
option button.

9.

Click the OK button.

Initiator Management

In a vSHARE HP VMA SAN Gateway environment, the I/O ports on the hosts (for

example, database servers or application servers) that access LUNs called

initiators

and the FC ports on HP VMA SAN Gateways themselves are called as

targets

.

The Initiator Management page enables you to define initiator groups and add or

remove initiators to those groups.

vSHARE enables you to control access to LUNs on an initiator-by-initiator basis

or by defining initiator groups (igroups).

Adding or Deleting Initiator Groups

To add an initiator group:

1.

Select vSHARE > Manage Initiators in the VMA Web Interface.

The Initiator Management page appears.

2.

Click the Add igroup button in the Initiator Groups table.

Figure B.25 Initiator Management Page