Placing the library on-line or off-line, Powering off the library, Using the ocp – HP ESL E-series Tape Libraries User Manual

Page 52

Advertising
background image

4.

Power on the power switch (see

Figure 27

).

NOTE:

The library requires several minutes to power on. Nothing displays on the OCP for the

first few minutes of this process.

Placing the library on-line or off-line

To place the library on- or off-line:

1.

With the library powered on, press the Ops button on the OCP to access the Operations screen.

2.

Select Cabinet and use the Up and Down arrows to take the library off-line or place it on-line.
For more information on the Operations screen, see

Operations screen

.

Powering off the library

To power off the library:

1.

Place the library off-line, see

Placing the library on-line or off-line

.

The library robotics completes any current commands and then stops.

2.

Verify that the OCP display indicates “Off-line” from the Operations screen.

3.

Verify that the media picker is empty.

4.

Verify that no backups are in process.

5.

Turn off the power switch located on the front of the library (see

Figure 27

).

6.

Wait for the library to complete the shutdown process. (This usually takes 30 seconds, but may

take up to two minutes.)

7.

Open the back door of the library cabinet and flip the breaker switches to the off position (left).

The breaker switches are on the power distribution unit located on the bottom left side of the

library cabinet.

NOTE:

When powering off the library, ensure that the two breaker switches on the power

distribution unit are in the off (left) position.

Using the OCP

The OCP is located on the front of the library. The menus on the OCP allow you to obtain information

about the library, execute library commands, and test library functions.
The status bar at the top of the OCP displays library status at all times, at the left of the bar. The status

can be Online, Going Online, or Offline, followed by a warning level: OK, Warning, or Critical.

In addition, when a library firmware upgrade is in progress, Upgrading FW is displayed on the right

side of the status bar.

NOTE:

If the library reports a status of Warning or Critical, check the Health Status screen to see which

component is causing that status. See

Viewing library health status information (standalone libraries

only)

for details.