For the c7000 BladeSystem enclosure, use the following table to determine which external storage enclosures
to use when zoning the external storage to the server blades.

For example, as shown in the table, if a full-height server blade is installed in device bay 1-8 of a c7000
enclosure, and the P700m Controller is installed in server mezzanine slot 2; the 3Gb SAS BL Switch must
be installed in BladeSystem interconnect bay 5, 6, 7, or 8 and it should be assigned a zone group that is
in an external storage enclosure attached to 3Gb SAS BL Switch ports 1, 2, 3, or 4.

Zone groups must be in
storage enclosures

nl

connected to these 3Gb
SAS BL Switch ports

BladeSystem

nl

c-Class

nl

interconnect bay

BladeSystem

nl

c-Class

nl

device bay

Mezzanine slot

Server type

BladeSystem

nl

c-Class

nl

enclosure

nl

model

1 – 4

3/4

1 – 8

1

Half height

c7000

5 – 8

3/4

9 – 16

1 – 4

5/6/7/8

1 – 8

2

5 – 8

5/6/7/8

9 – 16

1 – 4

3/4

Any

1

Full height

1 – 4

5/6/7/8

Any

2

5 – 8

5/6/7/8

Any

3

1 – 4

5/6

1A – 8A

Any

Half height

nl

Double dense

nl

(BL2x220c)

1 – 4

7/8

1B – 8B

5 – 8

5/6

9A – 16A

5 – 8

7/8

9B – 16B

1 – 4

3/4

Any

1

Full height

nl

Double wide

nl

(BL680c G7)

1 – 4

5/6/7/8

Any

2

5 – 8

5/6/7/8

Any

3

1 – 4

5/6/7/8

Any

4

5 – 8

3/4

Any

5

5 – 8

5/6/7/8

Any

7

As shown in the tables, each HP 3Gb SAS BL Switch is organized in two sets of connections. These two
connection sets are based on the two SAS expanders housed in the switch. Each SAS expander provides
four external SAS ports and is connected internally to eight blade bays. This organization may have
implications for best system configuration practices according to the hardware in use.

The VSM GUI displays the following warning message if a configuration is attempted that violates these
requirements. All such configurations are unsupported by HP.

8