HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 82

Advertising
background image

Resetting the switch or attached storage enclosures

To restart the switch or an attached zoned SAS storage enclosure such as the MDS600, use the
following command description:

Syntax

<target> reset

[

hardware|software

] [

forced

]

Example 1: This example demonstrates restarting the switch:

=> sw local reset hardware

Example 2: This example demonstrates restarting the VSM application on the switch (required after
updating switch network settings):

=> sw local reset software

Example 3: This example demonstrates restarting storage enclosures connected to ports 3 and 4
of the switch in interconnect bay 7:

=> sw local se portbox=73:1,74:1 reset hardware

Example 4: This example demonstrates restarting all storage enclosures connected to the switch:

=> sw local se all reset hardware

NOTE:

If the

reset

command does not execute successfully or displays an error message,

consider the following:

Storage enclosure model—Only supported storage enclosures can be reset.

Switch status—If the status is a value other than Active or Not Redundant, resetting the storage
enclosure is not allowed.

Server blade status—All server blades in the c-Class enclosure must be powered off to perform
this task.

VSM activity—If the VSM GUI or VSM CLI is already processing a firmware update on a
switch or storage enclosure, this command request cannot be processed.

Issue the

rescan

command to ensure displayed information is up-to-date. Correct any issues before

proceeding.

82

Performing common tasks

Advertising