Icron Four-Port USB 3-2-1 Raven 3104 Point-to-Point Extender System (328') User Manual

Page 15

Advertising
background image

14

PROBLEM

CAUSE

SOLUTION

A USB 3 device is

not enumerating

as USB 3, or the

operating system

is notifying

the user that

the device can

“Perform Faster

if connected to a

USB 3 port”.

1. The USB device is

malfunctioning.

2. The computer does not

recognize the USB device.

3. The application software for

the USB device is not

operating.

4. The USB 3 port on the

computer is malfunctioning.

5. The USB extender is

malfunctioning.

1. Disconnect the extender from the computer.

2. Connect the USB 3 device directly to the host

computer.

3. If the device does not operate as expected as a

USB 3 device, consult the user documentation

for that device or try a different USB port on the

host computer.

4. Update the host computer BIOS, chipset or USB

controller drivers from the manufacturer’s

website.

5. If the device operates as USB 3 device when

directly connected to the computer, connect

another USB 3 device to the extender and

reconnect it to the host computer.

6. If the second device does not operate as a

USB 3 device, the extender may be

malfunctioning. Contact

Technical Support

for assistance.

7. If the second device operates as a USB 3

device as expected, the first device may not

be compatible with this extender. Contact

Technical Support

.

All LEDs are

flashing and

the system is

operational.

1. Unit is or was operating at an

unsafe temperature.

1. Check ambient temperature. Ensure

temperature does not exceed 50°C (122°F).

2. Power cycle the unit to remove LED status.

All LEDs are

flashing and the

system is NOT

operational.

1. Unit has exceeded safe

operating temperature.

1. Remove external sources of heat or change

location of the unit.

2. Power cycle the unit to return to operation.

LEDs are scrolling

LEFT to RIGHT,

starting with

STATUS.

1. Unit is programming.

1. Wait for the unit to finish programming.

Advertising