port is disabled.

::= { interfaceEntry 16}

interfaceFrameFormat OBJECT-TYPE

SYNTAX

INTEGER {

none (1),
sonet-sts-3c (2),
sdh-stm-1 (3),
ds3 (4),
e3 (5)
}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

The format of the frames exchanged on this port.
For a 155 Mbits LAN port, 2 formats are supported:
sonet-sts-3c and sdh-stm-1. It can only be
modified if the port atm access is UNI or NNI.
The frame format of a wan port cannot be modified.
For the other ports, the frame format cannot be
modified and is always returned as none.
The frame format can be changed only when the port
is disabled.

::= { interfaceEntry 17}

-- switch statistics

globalThroughputStats

OBJECT IDENTIFIER ::= { physical 5 }

globalThroughputMonitoring OBJECT-TYPE

SYNTAX

INTEGER {

on (1),
off (2)

}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

When on, the switch throughput is monitored.
When off, the switch thoughput is not monitored.
Note that the monitoring decreases the system
overall performances.

::= { globalThroughputStats 1 }

globalThroughputAggregateOutCells OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The total number of cells transmitted from the

switch.
Note that this value is the aggregate throughput
of all the ports on several minutes.

::= { globalThroughputStats 2 }

receiveTopList OBJECT-TYPE

SYNTAX

DisplayString

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

214

ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Advertising