IBM SG24-4817-00 User Manual

Page 278

Advertising
background image

This soft copy for use by IBM employees only.

of a slot/subslot. This information is a summary of
the objects in the modules branch.

No entry in this table exists for an empty slot.

::= { staticSummary 1 }

staticSummaryEntry OBJECT-TYPE

SYNTAX

StaticSummaryEntry

ACCESS

not-accessible

STATUS

mandatory

DESCRIPTION

A predefined collection of MIB objects whose

values can be retrieved as a single field.

INDEX

{ ssSlotIndex, ssSubSlotIndex }

::= { staticSummaryTable 1 }

StaticSummaryEntry ::=

SEQUENCE {

ssSlotIndex

INTEGER,

ssSubSlotIndex

INTEGER,

ssValues

OCTET STRING

}

ssSlotIndex OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The slot number of the slot to which this

entry pertains.

::= { staticSummaryEntry 1 }

ssSubSlotIndex OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The subslot number to which this entry pertains.

It is associated with a slot number. Motherboards are
always located in subslot one, (e.g. <slot>.1). However,
daughter cards can reside on any subslot within the range
(2 ... 8), (e.g. <slot>.<2 .. 8>).

::= { staticSummaryEntry 2 }

ssValues OBJECT-TYPE

SYNTAX

OCTET STRING

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The OIDs and values of the objects to be summarized,

given as an octet string in the

New Summary

format.

NEW_SUMMARY DEFINITION ::= BEGIN

IMPORTS TimeTicks FROM RFC1155-SMI;

Message ::= CHOICE OF {

Message_0

}

262

ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Advertising