IBM SG24-4817-00 User Manual

Page 283

Advertising
background image

This soft copy for use by IBM employees only.

ocPowerOutputWattageAvailable

Gauge,

ocPowerOutputUnmanagedWattageAlloc

Gauge

}

ocPowerOutputType OBJECT-TYPE

SYNTAX INTEGER {

plusFiveVolt(1),

-- + 5 Volt

minusFiveVolt(2),

-- - 5 Volt

plusTwelveVolt(3),

-- +12 Volt

minusTwelveVolt(4),

-- -12 Volt

plusTwoVolt(5)

-- + 2 Volt

}

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Identifies the power (voltage) line type for which this

entry contains power budget information.

::= { ocPowerOutputEntry 1 }

ocPowerOutputVoltageLevel OBJECT-TYPE

SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION

In millivolts (1/1000 Volt), the actual voltage level

for this voltage type as sensed on the backplane.

This

voltage is supplied by all operational power supplies.

::= { ocPowerOutputEntry 2 }

ocPowerOutputWattageCapacity OBJECT-TYPE

SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION

In hundredths of a Watt (1/100 Watt), the maximum

wattage for the voltage line that is output by all
operational power supplies combined.

::= { ocPowerOutputEntry 3 }

ocPowerOutputWattageConsumed OBJECT-TYPE

SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION

In hundredths of a Watt (1/100 Watt), the wattage

consumed by all hub modules.

For a given voltage line,

this object

s value is the sum total of the power

consumed by the hub itself, the Controller Modules
and all power-enabled slots containing IBM 8260 modules.
If power fault-tolerant mode is enabled (when it was
previously disabled), this object

s value is increased

by the amount of power reserved for the voltage line.
If power fault-tolerant mode is disabled (when it was
previously enabled), this object

s value is decreased

by the amount of power that is returned to the available
power budget for the voltage line.

::= { ocPowerOutputEntry 4 }

Appendix E.

IBM ATM Campus Switch Private MIBs

267

Advertising