This soft copy for use by IBM employees only.

ACCESS read-write
STATUS mandatory
DESCRIPTION

Writing a reset(2) will reset every module in the stack

without changing the current configuration and will zero
all counters.

::= { conc 2 }

concNumSlots OBJECT-TYPE

SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION

The number of slots in this concentrator.

This value is

the sum total of all payload slots plus any slots reserved
for controller modules.

For example, for an IBM 8260 agent

operating in a 17-slot IBM 8260 hub, this object will have
the value 19 (17 payload slots plus 2 controller slots).

::= { conc 3 }

concProfile OBJECT-TYPE

SYNTAX OCTET STRING (SIZE(1..3))
ACCESS read-only
STATUS mandatory
DESCRIPTION

A bit string containing always 00 00 00.

::= { conc 4 }

concDescr OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION

A textual string containing information about the hub type.

::= { conc 5 }

-- The env Group

-- This group represents the concentrator

s environment.

It is available

-- from agents that are acting as a concentrator master.

envTempStatus OBJECT-TYPE

SYNTAX INTEGER {

okay(1),
extremeTemp(2),
warning(3)
}

ACCESS read-only
STATUS mandatory
DESCRIPTION

The overall temperature status for this concentrator.

This object

s value is an aggregate of all the temperature

probes in the concentrator, such that, when at least one probe
reports extreme temperature, this object will have the value
extremeTemp(2).

This object will have the value warning(3)

prior to reporting the value extremeTemp(2) as a means of
warning of a possible hub overheat condition.