optionalFeatureHardwareVersion

DisplayString,

optionalFeatureNumberOfPorts

INTEGER,

optionalFeatureDescription

DisplayString

}

optionalFeatureSlotIndex OBJECT-TYPE

SYNTAX

INTEGER (1..64)

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The slot number for this optional feature card.

::= { optionalFeatureEntry 1 }

optionalFeatureSubSlotIndex OBJECT-TYPE

SYNTAX

INTEGER (1..16)

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The sub-slot number for this optional feature card.

::= { optionalFeatureEntry 2 }

optionalFeatureHardwareVersion OBJECT-TYPE

SYNTAX

DisplayString

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The Part Number (P/N) and Engineering Change (EC) level
and Plant Location for this optional feature card.

::= { optionalFeatureEntry 3 }

optionalFeatureNumberOfPorts OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The number of ports present on this feature card.

::= { optionalFeatureEntry 4 }

optionalFeatureDescription OBJECT-TYPE

SYNTAX

DisplayString (SIZE (0..255))

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

A textual description of this optional feature.
This description is blank when no description is available.

::= { optionalFeatureEntry 5 }

-- Cross-Connect Table

connections

OBJECT IDENTIFIER ::= { node 4 }

-- VCL Cross Connect Table

vcXConnectTable

OBJECT-TYPE

SYNTAX

SEQUENCE OF VcXConnectEntry

216