B&B Electronics TB5P508SR-2PK - Quick Start Guide User Manual

Quick start guide

Advertising
background image

Documentation Number DRAFT pn#8096R003 VESR9xx-0712qsg

C

C

h

h

e

e

c

c

k

k

f

f

o

o

r

r

A

A

l

l

l

l

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

Vlinx VESR9xx module

This Quick Start Guide

CD with Vlinx Manager s/w and manuals

Network cable (not included)

Serial cable(s) (not included)

10 to 48V DC (6.0W) Power Supply (not
included)
































































































Quick Start

Guide

Vlinx VESR9xx Serial

Servers

1

I

I

n

n

s

s

t

t

a

a

l

l

l

l

t

t

h

h

e

e

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

2

Connect a 10 to 48 VDC (58 VDC Max) power supply

(6.0 W required).

Connect the network cable from the serial server to a

network drop using a standard network cable.

Connect the serial device(s):

o

RS-232 with DB9: straight-through for DCE
device, null modem for DTE device

o

RS-232/422/485 with terminal blocks: see
Appendix D for pinouts

UL Installation Information

One Conductor Per Terminal

Use Copper Wire Only

Wire Size: 28 to 16 AWG

Tightening Torque: 5 KG-CM

Wire Temperature Rating: 105 C Minimum (Sized for 60 C
Ampacity)

80 C Maximum Surrounding Ambient Air Temperature

SUITABLE FOR USE IN CLASS 1, DIVISION 2 GROUPS A, B, C, AND D

HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.

WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY

COMPONENT MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2.

L

L

E

E

D

D

S

S

t

t

a

a

t

t

u

u

s

s

LED

STATUS

Ready

Blinks if system is operating correctly

Port 1

On indicates serial port open, blinks when data present on
serial port

Port 2

Same as Port 1
(Present on 2 port units only)

Link

On indicates Ethernet operating in 100BaseTX, blinks
when data present on Ethernet link


3

M

M

o

o

d

d

e

e

S

S

w

w

i

i

t

t

c

c

h

h

Hold in Mode switch for…

Result

0 to 2 seconds

Initiates a Hardware Reset

2 to 10 seconds

Enters Console Mode

More than 10 seconds

Resets to Factory Defaults


4

I

I

n

n

s

s

t

t

a

a

l

l

l

l

V

V

l

l

i

i

n

n

x

x

M

M

a

a

n

n

a

a

g

g

e

e

r

r

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

Insert the included CD and it should autostart

Follow the prompts to install the Vlinx Manager
software.

Note: Be sure you have administrative rights & disable firewalls.

5

S

S

e

e

t

t

u

u

p

p

V

V

l

l

i

i

n

n

x

x

M

M

a

a

n

n

a

a

g

g

e

e

r

r

S

S

o

o

f

f

t

t

w

w

a

a

r

r

e

e

Open Vlinx Manager: click
StartProgramsB&B
ElectronicsVlinxVlinx ManagerVESR
Serial Server

The Discovery page opens

To configure via the network, select Network.

If you know the IP address, select The device is
at this address
, and type in the address.If not,
select I don’t know the IP address of the device.

Click Connect.

O

O

R

R

S

S

e

e

t

t

u

u

p

p

t

t

h

h

e

e

W

W

e

e

b

b

I

I

n

n

t

t

e

e

r

r

f

f

a

a

c

c

e

e

Open a browser and type the IP address of the
serial server in the Address Bar.

When the serial server is found, the
Configuration window appears.

6

Advertising