SPECIFICATION

MDR-20-5

MDR-20-12

MDR-20-15

MDR-20-24

MODEL

DC VOLTAGE

RATED CURRENT

CURRENT RANGE

RATED POWER

OUTPUT

VOLTAGE ADJ. RANGE

LINE REGULATION

LOAD REGULATION

SETUP, RISE TIME

Note.5

HOLD UP TIME (Typ.)

VOLTAGE RANGE

FREQUENCY RANGE

EFFICIENCY (Typ.)

AC CURRENT (Typ.)

INPUT

INRUSH CURRENT (Typ.)

SAFETY STANDARDS

HARMONIC CURRENT

EMS IMMUNITY

WORKING HUMIDITY

WORKING TEMP.

DC OK ACTIVE SIGNAL (max.)

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

MTBF

DIMENSION

OTHERS

NOTE

PACKING

OVERLOAD

OVER VOLTAGE

5V

12V

15V

24V

3A

1.67A

1.34A

1A

0 ~ 3A

0 ~ 1.67A

0 ~ 1.34A

0 ~ 1A

15W

20W

20W

24W

80mVp-p

120mVp-p

120mVp-p

13.5 ~ 16.5V

150mVp-p

21.6 ~ 26.4V

2.0%

1.0%

1.0%

1.0%

10.8 ~ 13.2V

4.75 ~ 5.5V

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

500ms, 30ms/230VAC

1000ms, 30ms/115VAC at full load

50ms/230VAC

20ms/115VAC at full load

85 ~ 264VAC

120 ~ 370VDC

47 ~ 63Hz

76%

80%

81%

84%

0.55A/115VAC

0.35A/230VAC

COLD START 20A/115VAC

40A/230VAC

105 ~ 160% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

5.75 ~ 6.75V

3.75 ~ 6V / 50mA

Protection type : Shut down o/p voltage, re-power on to recover

13.8 ~ 16.2V

9 ~ 13.5V / 40mA

17.25 ~ 20.25V

11.5 ~ 16.5V / 40mA

27.6 ~ 32.4V

18 ~ 27V / 20mA

-20 ~ +70

(Refer to output load derating curve)

20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

0.03%/

(0 ~ 50

Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

236.9K hrs min.

MIL-HDBK-217F (25

)

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25

of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.

File Name:MDR-20-SPEC 2007-07-09

UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant

Compliance to EN55011,EN55022 (CISPR22), EN61204-3 Class B

Compliance to EN61000-3-2,-3

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A

20W Single Output Industrial DIN Rail Power Supply

M D R - 2 0

s e r i e s

RIPPLE & NOISE (max.)

Note.2

VOLTAGE TOLERANCE

Note.3

ENVIRONMENT

PROTECTION

SAFETY &

EMC

(Note 4)

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

EMI CONDUCTION & RADIATION

Universal AC input/Full range

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

NEC class 2 / LPS compliant

LED indicator for power on

No load power consumption<0.75W

100% full load burn-in test

3 years warranty

Built in DC OK active signal

Features :

22.5*90*100mm (W*H*D)

0.19Kg; 72pcs/14.7Kg/0.91CUFT

LEAKAGE CURRENT

<1mA / 240VAC

FUNCTION

I/P-O/P:3KVAC

I/P-FG:1.5KVAC

O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

(accepts 120 ~ 370VDC but not certified)