Technical maintenance

Create

d

by EBCCW

0

0

:06

Page 61 of 68

5478EN-3

Maintenance schedule Spiral Elevator

.

Note! Make sure that the main switch has been switched off, and
safely isolated.

No. Execution

Interval

Remark

1.

Clean conveyor

Monthly

Regular cleaning depends on
product and environment

2.

Check the conveyor chain for
broken or missing conveyor
plates, replace if necessary

Daily

It is the task of the operator to
check this daily (see user’s
manual)

3.

Check the chain tension

Monthly

Remove a link if the chain is 38.5
mm too long. If more than two
links at the same time are to be
removed, contact the supplier.

4.

Check the sprocket wheel
and alignment. Replace or
align if necessary

Monthly

Faulty alignment of the sprocket
may cause permanent wear or
make the chain derail and can so
cause serious stoppages.

5.

Check the guide rails for
dents, damages and
connection

Monthly

Replace guide pieces if they
damage the products to be
transported. If the cause is bad
guide rail, contact the supplier.

6.

Clean inside below ends

Monthly

Accessible dirt will accumulate at
the bottom side.

7.

Check the drive for oil
leakage and undue noise

Monthly

Repair or replace if necessary.
See the troubleshooting list

8.

Check whether the Motor is
fastened well to the Spiral
Elevator. Tighten the bolts if
necessary

Monthly

Drive vibrations can make the
bolts loosen, then faulty alignment
of the drive can bend the shaft
and the chain may derail.

9.

Check the oil level in the
Motor, fill up if necessary

Monthly

Take a look at the gear motor
specifications of the manufacturer

10.

Change the oil in the Gear
motor

In accordance with the gear motor specifications of the
manufacturer