11. Smart T

uning Function (V

ersion V8.03.00.00 or Later)

138

[7] “Distance setting” window appears. Select the way to indicate the moving distance.



Fig. 11.38 Distance setting Window

(Select 2 position)

Fig. 11.39 Distance setting Window

(Assign distance)





For the following sections, the operation differs for the cases when indicating 2 points of positions and when

indicating the moving distance.

Ɣ

When indicating 2 points of positions

[8] Set the start position number setting box and click on

OK button.



Fig. 11.40 Distance setting Window

(Select 2 position)



[9] With the position set in the start position number and position set in the end position number as the

moving distance, overshoot judgment is conducted regarding the position set in the end position.

When the risk of overshooting is high, the message shows “Risk High”, while when it is low, shows “Risk

Low”.



Fig. 11.41 Overshoot Judgment Message

(Risk High)

Fig. 11.42 Overshoot Judgment Message

(Risk Low)