IAI America RCM-101-USB User Manual

Page 259

Advertising
background image

14.
Appendix

247

Code

Message

Description

212 JOG signal ON

This error indicates that the jog signal (JOG) was turned ON by the PLC

while the actuator was moving, and duplication of move commands

occurred as a result.

300 COM port open error

This error indicates that the COM port specified in the “application of setting

window” could not be opened.

The following causes are considered:

‚

The specified COM port does not exist.

‚

The specified COM port is already used in other application, etc.

301 Receive timeout error

This error indicates that a receive timeout error occurred while the PC

software was communicating with the connected controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (data turning into garbage,

etc.)

[3] The controller power was cut OFF.

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

[3] Check if the controller power is supplied. If the problem still

persists, contact IAI.

302 Receive buffer overflow This error indicates that the receive buffer overflowed when a response

message was received from the controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (data turning into garbage,

etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise. If the problem still persists, contact IAI.

303 Receive overrun

This error indicates that a receive overrun occurred at the COM port on the

PC when a response message was received from the controller.

Select a lower baud rate in the “application of setting window.”

304 Receive framing error

This error indicates that a receive framing error occurred when a response

message was received from the controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (garbled data, etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

If the problem still persists, contact IAI.