Timer

96

 

 

Summit T3‐16 PCI Express Multi‐Lane Protocol Analyzer User Manual

5.22.3

Changing the Value of the Counter

To change the value of the counter:

1. Double‐click on the Counter.
2. Enter a new value in the pop‐up dialog. This causes the new value to appear in the 

counter button.

5.22.4

Deleting a Counter

To delete a counter

1. Right‐click on the Counter. 
2. Select Delete This Event. The counter will disappear from the event.

5.23 Timer

The Timer has two options which are Start and Reset. When set to Start it starts the timer 
and when set to Reset it resets the timer to its initial value. When the timer count is 
down to 0 the action is triggered.

The Global State timer can trigger, start an action. It can also affect some other timers 
and counters.

Note:

It is an invalid configuration for some events when you try and set a counter and timer 

when both channels are selected.

The timers have different colors for the Global State and Sequence State. Each color 
signifies a different meaning in the Global and Sequence states.

There are two Timers for the Global State and four Timers for the Sequence State.

Note:

Global timers/counters can be used by events from any direction as long as the events occur 

more than 380 ns apart. State timer/counters can be controlled only from one direction not 
both, meaning starting, reset and incrementing must be done from events occurring in the same 
direction of the selected timer/counter.