Appendix A. Troubleshooting

Cannot Connect to a Power Source

A.2

Power Wave® Manager User Manual

IM8002

Procedure

Details

6.

On the Connect tab, choose I do not know

the IP address of the welder.

7.

Click the Refresh List button.

Only one IP address should appear.

8.

Select the welder and click Connect.

TIP |

When you select the power source, the green

status light on the machine should begin to blink.

The system automatically takes you to the System

status section in Power Wave® Manager.

9.

Click Connection in the navigation tree.

10.

Select the welder and click Configure.

11.

Edit the Ethernet settings to those provided

by your IT department.

See page 4.3 for more details on the settings

available.

12.

Click OK.

The Welding Power Source resets and accepts its new

network settings.

13.

Unplug the Ethernet cable from the Welding

Power Source.

14.

Reconnect the Welding Power Source to the

plant network again.

The new settings should take effect.

Ethernet Settings Seem Valid but Still Cannot Connect

If you have checked the Ethernet settings, and they are valid, use the following information to verify

communications and physical connections:

Check the physical network connections to the computer and the power source. Check for a

solid green or yellow light near each Ethernet jack. If you see a light, the physical connections

are probably not the issue.

Cycle the power to the Welding Power Source (off then back on). The power source could still

have a residual network connection in its memory under some circumstances.

If you continue to have trouble connecting, verify the following:

Do you have multiple Ethernet adapters enabled? This could cause issues. Verify that the

Ethernet communications are going through a single adapter. To do this, temporarily disable

any additional adapters.

If you are using an Ethernet cable connection, try to temporarily disable any wireless

communication on the computer. This could help the computer to directly connect to the

Welding Power Source through the cable without interference.

If the computer is running some type of security software or firewall, this may block the IP

address of the Welding Power Source. Check with your local IT department.