Procedure: Enabling Arc Production Monitor
Appendix B. FANUC Robots
IM8002
Power Wave® Manager User Manual
B.11
You identify the Digital Output port number for an alarm (log event and alarm latch) by setting the system
variable:
$AWELEPM[equip].$ALARM_PNUM
The Digital Output port number for a fault level alarm is set in:
$AWELEPM[equip].$FAULT_PNUM
Wire Monitor Setup Menu
Another feature of Lincoln Production Monitoring™ allows you to monitor the filler wire used and post an
alarm when the wire supply is below a user-specified threshold. The Arc Production Monitor option
includes a Wire Status menu for setting the warning threshold value and for resetting the wire supply. The
Wire Status menu can be found by pressing the STATUS pendant key, then selecting F1 (TYPE) and
choosing Wire. The menu appears as shown in Figure 11.3.
Figure 11.3 Wire Monitor Setup