Cable Settings and Tests

Chapter 6. Power Source Settings

IM8002

Power Wave® Manager User Manual

6.3

Cable Settings and Tests

The Cable settings and tests section allows you to configure and test your welding cables and sense leads

for the Welding Power Source to which you are connected.

Sense Lead Settings Tab

Use these settings to enable or disable automatic hardware sense lead selection or to modify the behavior

through manual settings. For most applications, the Automatic hardware sense lead selection is the best

method to use. This method reduces the chance of fairing and losing tips due to sense lead losses.

NOTE |

The Sense lead settings tab is only available for those

Welding Power Sources that do not have DIP switches for

modifying the sense lead location. The settings are also not

available for Welding Power Sources that do not support

changing the sense lead selection.

Figure 6.2 Sense Lead Settings Tab

Enabling Work Sense Lead

You can configure the system to force sense arc voltage from the work sense lead (21 lead) instead of

the negative output stud. This requires connecting to the voltage sense connector and attaching the

work lead to the work.
To enable the work sense lead:

Procedure

Details

1.

Remove the check mark from the Automatic

hardware sense lead selection checkbox.

2.

Place a check mark in the Enable remote

voltage sense leads checkbox.

3.

Click the Apply settings button.