Terminal history size – Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual

Page 160

Advertising
background image

Page 159

Allied Telesis
AT-8000S-S94-3.0 Command Line Interface User’s Guide

Parameters

This command has no arguments or keywords.

Default Configuration

The default configuration for all terminal sessions is defined by the history line configuration command.

Command Mode

User EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example disables the command history function for the current terminal session.

terminal history size

The terminal history size user EXEC command configures the command history buffer size for the current
terminal session. Use the no form of this command to reset the command history buffer size to the default setting.

Syntax

terminal history size number-of-commands

terminal no history size

Parameters

number-of-commands—Specifies the number of commands the system may record in its command history

buffer. (Range: 10-247)

Default Configuration

The default command history buffer size is 10.

Command Mode

User EXEC mode

User Guidelines

The terminal history size user EXEC command configures the size of the command history buffer for the current
terminal session. Use the history line configuration command to change the default size of the command history
buffer.

The maximum number of commands in all buffers is 256.

console# terminal no history